The electrical distribution system of a data center is designed to provide a reliable and efficient power supply to the IT equipment. It comprises a range of electrical components that work together to distribute power from the substation to the computer room air conditioning (CRAC) units and other equipment in the data center. Here are the primary electrical flow components involved in the distribution of power:
- Substation: The substation is where the power is received from the utility company. The voltage level is usually high at this point.
- High Voltage Switchgear: The high voltage switchgear is used to isolate, control, and protect the electrical power transmission system. It is responsible for controlling the flow of electrical power and preventing overload or short circuits.
- Transformers: The transformers are used to reduce the voltage of the incoming power supply to the appropriate level for use in the data center. They convert the high voltage from the substation to a lower voltage level that can be used to power the IT equipment.
- Ring Main Units (RMUs): RMUs are used to distribute power to the various areas of the data center. They act as switchgear and are responsible for directing power to the transformers and other electrical components.
- Low Voltage Switchgear: The low voltage switchgear is used to control and protect the electrical power distribution system within the data center. It is responsible for directing power to the power distribution units (PDUs).
- Power Distribution Units (PDUs): PDUs are used to distribute power to the CRAC units and other equipment in the data center.
- Computer Room Air Conditioning (CRAC) Units: CRAC units are responsible for cooling the data center and maintaining a stable temperature for the IT equipment.
- Uninterruptible Power Supply (UPS) Systems: UPS systems are used to provide backup power in the event of a power outage. They use batteries to provide a continuous power supply to the IT equipment, allowing it to continue operating until the main power supply is restored.
- Backup Generators: Backup generators are used to provide power in the event of a prolonged power outage. They are typically fueled by diesel or natural gas and are designed to provide continuous power to the data center for an extended period.
Overall, the electrical flow components of a data center work together to provide a reliable and efficient power supply to the IT equipment. By incorporating redundancy and resilience into the power distribution system, data centers can ensure that they remain operational even in the event of a power outage or failure of an electrical component.